You are now visiting the Philips lighting website. A localized version is available for you.
Suggestions
    • Dimming the next step in energy saving

      HF-Ri TD 3 14/24 TL5 E+ 195-240V
      HF-Ri TD 3 14/24 TL5 E+ 195-240V
      HF-Regulator Intelligent Touch DALI for TL5/TL-D/PL-L lamps

      HF-Ri TD 3 14/24 TL5 E+ 195-240V

      Order code: 15676500

      Full product code: 871829115676500

      Downloads

      Spec Sheet
      Size:420.1 kB

      See all downloads

    Specifications Show all

    General information
    Application code
    E+
    Type version
    mk3
    Lamp type
    TL5
    Number of lamps
    3 piece/unit
    Number of products on MCB (16 A type B) (nom.)
    16
    Automatic restart
    Yes
    Operating and electrical
    Input Voltage
    195-240 V
    Input frequency
    50 to 60 Hz
    Operating frequency (max.)
    110 kHz
    Operating frequency (min.)
    45 kHz
    Ignition method
    Warm Start
    Crest factor (max.)
    1.7
    Power factor 100% load (nom.)
    0.95
    Ignition time (max.)
    1 s
    Mains voltage performance (AC)
    -8%-+6%
    Mains voltage safety (AC)
    -10%-+10%
    Earth leakage current (max.)
    0.5 mA
    Inrush current width
    0.26 ms
    Standby power consumption (max.)
    0.25 W
    Ballast factor (nom.)
    1.0
    Inrush current peak (max.)
    31 A
    Efficiency at full load [%]
    90.54 %
    Wiring
    Connector type input terminals
    WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
    Cable capacity output wires mutual (max.)
    200 pF
    Connector type output terminals
    WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
    Connector type control input terminals
    WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
    Wire strip length
    8.0-9.0 mm
    Dual fixture master/slave
    Yes  [ Master/Slave operation possible]
    Control input terminal cross section
    0.50-1.00 mm²
    Input terminal cross section
    0.50-1.00 mm²
    Output terminal cross section
    0.50-1.00 mm²
    Auto-insert (ALF/ADS) wire cross section
    0.75 mm²
    Cable capacity output wires to earth (max.)
    200 pF
    System characteristics
    Rated ballast-lamp power
    14/24 W
    Rated lamp power on TL-D
    18 W
    System power on TL-D
    57.6 W
    Lamp power on TL-D
    17 W
    Power loss on TL-D
    6.6 W
    Rated lamp power on PL-L
    18/24 W
    System power on PL-L
    50.3/75.2 W
    Lamp power on PL-L
    15/22.9 W
    Power loss on PL-L
    5.3/6.5 W
    Rated lamp power on TL5
    14/24 W
    System power on TL5
    49.1/77.2 W
    Lamp power on TL5
    15/23.3 W
    Power loss on TL5
    4.1/7.3 W
    Rated lamp power on TL5 ECO
    13/20 W
    System power on TL5 ECO
    43.5/66.5 W
    Lamp Power on TL5 ECO
    13.6/20.1 W
    Rated lamp power on TL-D ECO
    16 W
    System power on TL-D ECO
    46.5 W
    Power loss on TL-D ECO
    5.4 W
    Lamp power on TL-D ECO
    13.7 W
    Power loss on TL5 ECO
    2.7/6.2 W
    Temperature
    T-ambient (max.)
    50 °C
    T-ambient (min.)
    -25 °C
    T storage (max.)
    80 °C
    T storage (min.)
    -40 °C
    T case lifetime (max.)
    75 °C
    T-Case maximum (max.)
    75 °C
    Stable lamp operation temperature
    15°C
    T-Ignition (max.)
    50 °C
    T-Ignition (min.)
    -25 °C
    Controls and dimming
    Control interface
    TD
    Regulating level power
    1%-100%
    Control input protection
    Yes (Basic insulation)
    Mechanical and housing
    Housing
    L 360x39x22
    Emergency operation
    Battery voltage lamp ignition
    198-254 V
    Battery voltage lamp operation
    176-254
    Approval and application
    Energy efficiency index
    A1 BAT
    IP classification
    IP 20  [ Ingress Protection 20]
    EMI 9 kHz ... 30 MHz
    EN55015
    EMI 30 MHz ... 1,000 MHz
    EN 55022 Class B
    Safety standard
    IEC 61347-2-3
    Performance standard
    IEC 60929
    Quality standard
    ISO 9000:2000
    Environmental standard
    ISO 14001
    Harmonic current emission standard
    IEC 61000-3-2
    EMC immunity standard
    IEC 61547
    Vibration standard
    IEC68-2-6 F c
    Bumps standard
    IEC 68-2-29 Eb
    Humidity standard
    EN 61347-2-3 clause 11
    Approval marks
    CE marking
    ENEC certificate
    VDE-EMV certificate
    Temperature marking
    Yes
    Emergency standard
    IEC 60598-2-22
    Humming and noise level
    Inaudible
    Product data
    Full product code
    871829115676500
    Order product name
    HF-Ri TD 3 14/24 TL5 E+ 195-240V
    EAN/UPC – product
    8718291156765
    Order code
    15676500
    SAP numerator – quantity per pack
    1
    Local code description
    REATOR ELETRONICO FLUOR HF-Ri TD314E+
    Numerator – packs per outer box
    10
    SAP material
    913700679066
    Net Weight (Piece)
    0.377 kg
    Installation Diagrams
    Downloads
    Leaflets
    Visuals

    Recently Viewed

    • Add product
       
    • Add product
       
    • Add product
       
    Add product